Applies to: ZWCAD 2018, ZWCAD 2017
With solution below, we can migrate the settings from client A to client B (including search path, menu setting, etc)
1, keep ZWCAD closed, copy this folder from A to B, replace the current one.
C:\Users\UserName\AppData\Roaming\ZWSoft\ZWCAD\2017
2, export this registry to client A, and double-click to install it on client B
HKEY_CURRENT_USER\Software\ZWSoft\ZWCAD\2017
After the two steps, it will work.
Note:
For 2017, there are some path in the registry include user name, so please make sure the user name is the same, or you cannot import it and use it directly. This issue doesn't exist in 2018, so we suggest the customer upgrade to 2018 to avoid such issue.
For custom palette in TP, you need to make sure to copy the dwg files of the blocks defined in tool palettes to the same path in the computer which you want to migrate to, and export and import the custom palette as below figure shown. This is not available on 2017.